120W 24V DIN Rail Industrial Power Supply with Corrosion Resistant Metal Enclosure

Basic Properties
Place of Origin: China
Brand Name: GWSpower
Certification: CE, FCC, RoHS
Model Number: GWS-DP120-24
Trading Properties
Minimum Order Quantity: 1
Payment Terms: T/T,Western Union
Supply Ability: 500000pcs/month
Specifications
Output Power: 120W Input Voltage: 90-264VAC
Frequency Range: 47Hz-63Hz Output Voltage: 24VDC
Output Current: 5A Operation Temperature: -40℃~+70℃
Product Description
120W/24V DIN Rail Industrial Power Supply
Overview

The GWS-DP120-24 is a 120W DIN Rail power supply that complies with German industrial standards. It is suitable for installation on TS-35/7.5 or TS-35/15 rails and features a full-range AC input of 90 VAC to 264 VAC, all of which comply with the harmonic current specifications outlined in the EN 61000-3-2 standard for the European Union.

The metal enclosure design facilitates improved heat dissipation, with an efficiency of up to 87%. It operates in ambient temperatures ranging from -40°C to 70°C under air-cooled conditions. Equipped with constant-current mode overload protection, it is suitable for a wide range of inductive or capacitive load applications. Comprehensive protection features and compliance with relevant certifications for industrial control equipment make it a highly competitive power supply solution for industrial applications.

Technical Specifications
Model GWS-DP120-24
Output
Group of Output 1
Rated Output Voltage 24VDC
Factory Default Output Voltage 24-24.2VDC (Vin: 220VAC / Load: 0A)
Rated Output Current 5.0A
Output Current Range 0-5.0A
Rated Output Power 120W
Total Peak Output Power Total Peak Power: 160W (Sustained for 10 seconds at 220 VAC)
Peak Output Current 6.5A (Sustained for 10 seconds at 220 VAC)
Ripple Noise Peak-to-peak ≤ 100 mV. (Measurement method: Connect 0.1 uF and 47 uF capacitors in parallel across the terminal and measure at a bandwidth of 20 MHz.)
Output Voltage Regulation Range 22.5-28VDC
Voltage Regulation Accuracy ±3% (@ 90-264VAC input, 100% load)
Linear Regulation ±0.5% (@ 90-264VAC input, 100% load)
Load Regulation ±1% (@90-264VAC input, 0-100% load)
Output Rise Time <1S @nominal input (100% load)
Output Settling Time >20ms @115VAC, >115ms @230VAC (100% load)
Voltage Overshoot ≤5%
Function
DC OK Relay contact maximum value: 125V/1A
Toggle Switch Standalone/Parallel operation function
Input
Input Voltage Range 90-264VAC
Rated Input Voltage Range 100-240VAC
Frequency Range 47Hz-63Hz
Rated Frequency 50Hz/60Hz
Start-up Voltage 90VAC
Efficiency >85% @115VAC, >87% @ 230VAC
Input Current <2.40A @115VAC, <1.20A @ 230VAC
Start-up Inrush Current <35A @ 115VAC& 230VAC
Power Factor >0.6
Protection Function
Overpower Protection 130-160W swing test (Test method: Continuously increase the output current until protection is triggered; Protection mode: swing test; automatically resumes normal operation after the overpower condition is resolved.)
Overvoltage Protection 30-36V Protection mode: Output self-locking protection is off; power-on is required to restore operation.
Overcurrent Protection 5.5-6.5A swing test (Test method: Continuously increase the output current until protection is triggered; Protection mode: swing test; the unit automatically resumes normal operation once the overcurrent condition is resolved.)
Short Circuit Protection Short-circuit the power supply's output terminals directly using a copper wire with sufficient cross-sectional area and a length of 15 cm ± 5 cm. The short-circuit may be maintained for an extended period; the unit automatically resumes normal operation once the short-circuit is resolved.
Operation Environment
Operation TEMP/ Humidity -40℃~+70℃, 20%-95%RH non-condensing
Storage TEMP/ Humidity -40℃~+85℃, 10%-95%RH non-condensing
Temperature Coefficient ±0.03%/℃ (0-50℃)
Vibration Frequency range: 10-500 Hz, acceleration: 2 G, 10 minutes per sweep cycle, with 6 sweep cycles along each of the X, Y, and Z axes
Shock Acceleration: 20 G, duration: 11 ms, with 3 shock tests along each of the X, Y, and Z axes
Altitude 2000 m
Safety and EMC Standard
Safety Standard EN IEC 62368-1 □Reference ☑Certification
Insulation Strength Input-Output: 3 kV AC/10 mA; Input-Enclosure: 1.5 kV AC/10 mA; Output-Enclosure: 0.5 kV DC/10 mA. Each test lasts 1 minute
Grounding Test Test conditions: 32 A for 2 minutes; ground impedance: <0.1 Ω.
Leakage Current Input to ground ≤3.5 mA; input to output ≤0.25 mA (Input 264 VAC, frequency 63 Hz)
Insulation Resistance Input-output: 10 MΩ
Electromagnetic Interference (EMI)
Conducted Interference EN55032, FCC Part 15 Class B
Radiated Interference EN55032, FCC Part 15 Class B
Harmonic Current EN61000-3-2 Class D
Conducted Immunity EN61000-4-6 Level 3
Radiated Immunity EN61000-4-3 Level 3 Class B
Power-Frequency Immunity EN61000-4-8 Level 3
Electrostatic Immunity EN61000-4-2 Level 4 Class B
Fast Pulse Groups EN61000-4-4 Level 4 Class B
Lightning Strikes (Surge) EN61000-4-5 Level 4 Class B
Interrupts, Dips EN61000-4-11
Others
Dimension 135*121*40mm
Net /Gross Weight 0.56kg/ 0.62kg
Warranty 5 years, lifelong maintenance
Notes

1. All specifications and parameters were measured at an input of 230 VAC, rated load, and an ambient temperature of 25°C.

2. Ripple and noise measurement method: Use a 12' twisted-pair cable with 0.1 μF and 47 μF capacitors connected in parallel at the terminals; measurements were taken at a bandwidth of 20 MHz.

3. Accuracy: Includes setting error, linear regulation, and load regulation.

4. The power supply should be considered part of the system. Electromagnetic compatibility verification must be performed in conjunction with the terminal equipment.

Dimension
GWS-DP120-24 DIN Rail Power Supply Dimension Diagram
Features
  • 90~264VAC input
  • 100% full load aging test
  • Meets safety and EMC standards
  • Standalone/Parallel operation function
  • High efficiency, long life, and high reliability
  • Operating temperature range: -40℃~+70℃
  • Protection functions: short circuit/overload/overvoltage
  • DC OK output voltage abnormal alarm signal switch function
Applications
  • Factory automation
  • Industrial control systems
  • Electromechanical equipment
  • Semiconductor manufacturing equipment