120W 12V DIN Rail Industrial Power Supply with Wide Operation Temperature Range

Basic Properties
Place of Origin: China
Brand Name: GWSpower
Certification: CE, FCC, RoHS
Model Number: GWS-DP120-12
Trading Properties
Minimum Order Quantity: 1
Payment Terms: T/T,Western Union
Supply Ability: 500000pcs/month
Specifications
Output Voltage: 12VDC Output Current: 10.0A
Output Power: 120W Input Voltage: 90-264VAC
Frequency Range: 47Hz-63Hz Ripple Noise: ≤100 MV
Product Description
120W/12V DIN Rail Industrial Power Supply
Product Overview

The GWS-DP120-12 is a 120W DIN Rail power supply conforming to German industrial standards. Designed for mounting on TS-35/7.5 or TS-35/15 rails, it features a full-range AC input from 90Vac to 264Vac and complies with EN61000-3-2 standards for EU-specified harmonic current specifications.

Utilizing a metal housing design for enhanced heat dissipation, this power supply achieves efficiency up to 88%. Under air circulation conditions, it operates in ambient temperatures ranging from -40°C to 70°C. With constant current mode overload protection, it is suitable for various inductive or capacitive loads. Comprehensive protection features and compliance with industrial control equipment certifications make this a highly competitive power supply solution for industrial applications.

Technical Specifications
ModelGWS-DP120-12
Output
Group of Output1
Rated Output Voltage12VDC
Factory Default Output Voltage12-12.2VDC (Vin: 220VAC / Load: 0A)
Rated Output Current10.0A
Output Current Range0-10.0A
Rated Output Power120W
Total Peak Output Power160W (Sustained for 10 seconds at 220 VAC)
Peak Output Current15A (Sustained for 10 seconds at 220 VAC)
Ripple NoisePeak-to-peak ≤ 100 mV
Output Voltage Regulation Range12.0-14.0VDC
Voltage Regulation Accuracy±3% (@ 90-264VAC input, 100% load)
Linear Regulation±0.5% (@ 90-264VAC input, 100% load)
Load Regulation±1% (@90-264VAC input, 0-100% load)
Output Rise Time<1S @nominal input (100% load)
Output Settling Time>20ms @115VAC, >115ms @230VAC (100% load)
Voltage Overshoot≤5%
Function
DC OKRelay contact maximum value: 125V/1A
Toggle SwitchStandalone/Parallel operation function
Input
Input Voltage Range90-264VAC
Rated Input Voltage Range100-240VAC
Frequency Range47Hz-63Hz
Rated Frequency50Hz/60Hz
Start-up Voltage90VAC
Efficiency>85% @115VAC, >88% @ 230VAC
Input Current<2.40A @115VAC, <1.20A @ 230VAC
Start-up Inrush Current<35A @ 115VAC& 230VAC
Power Factor>0.6
Protection Function
Overpower Protection144-180W swing test
Overvoltage Protection18-22V Protection mode: Output self-locking protection is off; power-on is required to restore operation
Overcurrent Protection12-17A swing test
Short Circuit ProtectionShort-circuit the power supply's output terminals directly using a copper wire with sufficient cross-sectional area and a length of 15 cm ± 5 cm
Operation Environment
Operation TEMP/ Humidity-40℃~+70℃, 20%-95%RH non-condensing
Storage TEMP/ Humidity-40℃~+85℃, 10%-95%RH non-condensing
Temperature Coefficient±0.03%/℃ (0-50℃)
VibrationFrequency range: 10-500 Hz, acceleration: 2 G, 10 minutes per sweep cycle, with 6 sweep cycles along each of the X, Y, and Z axes
ShockAcceleration: 20 G, duration: 11 ms, with 3 shock tests along each of the X, Y, and Z axes
Altitude2000 m
Safety and EMC Standard
Safety StandardEN IEC 62368-1 □Reference ☑Certification
Insulation StrengthInput-Output: 3 kV AC/10 mA; Input-Enclosure: 1.5 kV AC/10 mA; Output-Enclosure: 0.5 kV DC/10 mA. Each test lasts 1 minute
Grounding TestTest conditions: 32 A for 2 minutes; ground impedance: <0.1 Ω
Leakage CurrentInput to ground ≤3.5 mA; input to output ≤0.25 mA (Input 264 VAC, frequency 63 Hz)
Insulation ResistanceInput-output: 10 MΩ
Electromagnetic Interference (EMI)
Conducted InterferenceEN55032, FCC Part 15 Class B
Radiated InterferenceEN55032, FCC Part 15 Class B
Harmonic CurrentEN61000-3-2 Class D
Conducted ImmunityEN61000-4-6 Level 3
Radiated ImmunityEN61000-4-3 Level 3 Class B
Power-Frequency ImmunityEN61000-4-8 Level 3
Electrostatic ImmunityEN61000-4-2 Level 4 Class B
Fast Pulse GroupsEN61000-4-4 Level 4 Class B
Lightning Strikes (Surge)EN61000-4-5 Level 4 Class B
Interrupts, DipsEN61000-4-11
Others
Dimension135*121*40mm
Warranty5 years, lifelong maintenance
Product Dimensions
GWS-DP120-12 DIN Rail Power Supply dimensional diagram showing product measurements
Key Features
  • 90~264VAC input
  • 100% full load aging test
  • Meets safety and EMC standards
  • Standalone/Parallel operation function
  • High efficiency, long life, and high reliability
  • Operating temperature range: -40℃~+70℃
  • Protection functions: short circuit/overload/overvoltage
  • DC OK output voltage abnormal alarm signal switch function
Applications
  • Factory automation
  • Industrial control systems
  • Electromechanical equipment
  • Semiconductor manufacturing equipment

Notes:

1. All specifications and parameters were measured at an input of 230 VAC, rated load, and an ambient temperature of 25°C.

2. Ripple and noise measurement method: Use a 12' twisted-pair cable with 0.1 μF and 47 μF capacitors connected in parallel at the terminals; measurements were taken at a bandwidth of 20 MHz.

3. Accuracy: Includes setting error, linear regulation, and load regulation.

4. The power supply should be considered part of the system. Electromagnetic compatibility verification must be performed in conjunction with the terminal equipment.