240W 24V High Efficiency DIN Rail Industrial Power Supply for Automation and Control Systems

Basic Properties
Place of Origin: China
Brand Name: GWSpower
Certification: CE, FCC, RoHS
Model Number: GWS-DP240-24
Trading Properties
Minimum Order Quantity: 1
Payment Terms: T/T,Western Union
Supply Ability: 500000 pcs/month
Specifications
Output Voltage: 24VDC Output Current: 10A
Output Power: 240W Peak Power: 360W (10 Seconds)
Input Voltage: 90-264VAC Frequency Range: 47Hz-63Hz
Product Description
240W/24V DIN Rail Industrial Power Supply

The GWS-DP240-24 is a 240W DIN Rail power supply that complies with German industrial standards. It is suitable for installation on TS-35/7.5 or TS-35/15 rails and features a full-range AC input of 90 VAC to 264 VAC, all of which comply with the harmonic current specifications outlined in the EN 61000-3-2 standard for the European Union.

The metal enclosure design facilitates improved heat dissipation, with an efficiency of up to 90%. It operates in ambient temperatures ranging from -40°C to 70°C under air-cooled conditions. Equipped with constant-current mode overload protection, it is suitable for a wide range of inductive or capacitive load applications. Comprehensive protection features and compliance with relevant certifications for industrial control equipment make it a highly competitive power supply solution for industrial applications.

Technical Specifications
Model GWS-DP240-24
Output
Group of Output 1
Rated Output Voltage 24VDC
Factory Default Output Voltage 24.00-24.2VDC (Vin: 220VAC / Load: 0A)
Rated Output Current 10A
Output Current Range 0-10A
Rated Output Power 240W
Total Peak Output Power Total Peak Power: 360 W (Sustained for 10 seconds at 220 VAC)
Peak Output Current 15A (Sustained for 10 seconds at 220 VAC)
Ripple Noise Peak-to-peak ≤ 100 mV. (Measurement method: Connect 0.1 uF and 47 uF capacitors in parallel across the terminal and measure at a bandwidth of 20 MHz.)
Output Voltage Regulation Range 22.5-28VDC
Voltage Regulation Accuracy ±1% (@ 90-264VAC input, 100% load)
Linear Regulation ±0.5% (@ 90-264VAC input, 100% load)
Load Regulation ±1% (@90-264VAC input, 0-100% load)
Output Rise Time <2S @ nominal input (100% load)
Output Settling Time >20ms @ 115VAC, >50 ms @ 230VAC (100% load)
Voltage Overshoot ≤5.0%
Input
Input Voltage Range 90-264VAC
Rated Input Voltage Range 100-240VAC
Frequency Range 47Hz-63Hz
Rated Frequency 50Hz/60Hz
Start-up Voltage 90VAC
Efficiency >90.0% @115VAC, >91.0% @ 230VAC
Input Current <4.40A @115VAC, <2.20A @ 230VAC
Start-up Inrush Current <35A @ 115VAC& 230VAC
Power Factor >0.99 @ 115VAC, >0.93 @ 230VAC
Protection Function
Over-power Protection 288-360W swing test (Test method: Continuously increase the output current until protection is triggered; Protection mode: swing test; automatically resumes normal operation after the overpower condition is resolved.)
Over-voltage Protection 28-29V swing test (Short pins 1 and 2 of U8 to trigger the swing test; output returns to normal when the short is removed). Note: Do not apply an external voltage
Over-current Protection 12-15A swing test (Test method: Continuously increase the output current until protection is triggered; Protection mode: swing test; the unit automatically resumes normal operation once the overcurrent condition is resolved.)
Short-circuit Protection Short-circuit the power supply's output terminals directly using a copper wire with sufficient cross-sectional area and a length of 15 cm ± 5 cm. The short-circuit may be maintained for an extended period; the unit automatically resumes normal operation once the short-circuit is resolved.
Operation Environment
Operation TEMP/ Humidity -40℃~+70℃, 20%-95%RH non-condensing
Storage TEMP/ Humidity -40℃~+85℃, 10%-95%RH non-condensing
Temperature Coefficient ±0.03%/℃ (0-50℃)
Vibration Frequency range: 10-500 Hz, acceleration: 2 G, 10 minutes per sweep cycle, with 6 sweep cycles along each of the X, Y, and Z axes
Shock Acceleration: 20 G, duration: 11 ms, with 3 shock tests along each of the X, Y, and Z axes
Altitude 2000 m
Safety and EMC Standard
Safety Standards EN IEC 62368-1 ■Reference □Certification
Insulation Strength Input-Output: 3 kV AC/10 mA; Input-Enclosure: 1.5 kV AC/10 mA; Output-Enclosure: 0.5 kV DC/10 mA. Each test lasts 1 minute
Grounding Test Test conditions: 32 A for 2 minutes; ground impedance: <0.1 Ω.
Leakage Current Input to ground ≤3.5 mA; input to output ≤0.25 mA (Input 264 VAC, frequency 63 Hz)
Insulation Resistance Input-output: 10 MΩ
Electromagnetic Interference (EMI)
Conducted Interference EN55022, EN55024, FCC Part 15 Class B
Radiated Interference EN55022, EN55024, FCC Part 15 Class B
Harmonic Current EN61000-3-2 Class D
Conducted Immunity EN61000-4-6 Level 3
Radiated Immunity EN61000-4-3 Level 3 Class B
Power-Frequency Immunity EN61000-4-8 Level 3
Electrostatic Immunity EN61000-4-2 Level 4 Class B
Fast Pulse Groups EN61000-4-4 Level 4 Class B
Lightning Strikes (Surge) EN61000-4-5 Level 4 Class B
Interrupts, Dips EN61000-4-11
Others
Dimension 131*121*45mm
Net /Gross Weight 0.74kg/ 0.78kg
Warranty 5 years, lifelong maintenance
Dimension
GWS-DP240-24 DIN Rail Power Supply Dimensions Diagram
Features
  • 90~264VAC input
  • 100% full load aging test
  • Meets safety and EMC standards
  • High efficiency, long life, and high reliability
  • Operating temperature range: -40℃~+70℃
  • Protection functions: short circuit/overload/overvoltage
Applications

Factory automation, Industrial control systems, Electromechanical equipment, Semiconductor manufacturing equipment