240W 24V High Efficiency DIN Rail Industrial Power Supply for Automation and Control Systems
| Output Voltage: | 24VDC | Output Current: | 10A |
| Output Power: | 240W | Peak Power: | 360W (10 Seconds) |
| Input Voltage: | 90-264VAC | Frequency Range: | 47Hz-63Hz |
The GWS-DP240-24 is a 240W DIN Rail power supply that complies with German industrial standards. It is suitable for installation on TS-35/7.5 or TS-35/15 rails and features a full-range AC input of 90 VAC to 264 VAC, all of which comply with the harmonic current specifications outlined in the EN 61000-3-2 standard for the European Union.
The metal enclosure design facilitates improved heat dissipation, with an efficiency of up to 90%. It operates in ambient temperatures ranging from -40°C to 70°C under air-cooled conditions. Equipped with constant-current mode overload protection, it is suitable for a wide range of inductive or capacitive load applications. Comprehensive protection features and compliance with relevant certifications for industrial control equipment make it a highly competitive power supply solution for industrial applications.
| Model | GWS-DP240-24 |
|---|---|
| Output | |
| Group of Output | 1 |
| Rated Output Voltage | 24VDC |
| Factory Default Output Voltage | 24.00-24.2VDC (Vin: 220VAC / Load: 0A) |
| Rated Output Current | 10A |
| Output Current Range | 0-10A |
| Rated Output Power | 240W |
| Total Peak Output Power | Total Peak Power: 360 W (Sustained for 10 seconds at 220 VAC) |
| Peak Output Current | 15A (Sustained for 10 seconds at 220 VAC) |
| Ripple Noise | Peak-to-peak ≤ 100 mV. (Measurement method: Connect 0.1 uF and 47 uF capacitors in parallel across the terminal and measure at a bandwidth of 20 MHz.) |
| Output Voltage Regulation Range | 22.5-28VDC |
| Voltage Regulation Accuracy | ±1% (@ 90-264VAC input, 100% load) |
| Linear Regulation | ±0.5% (@ 90-264VAC input, 100% load) |
| Load Regulation | ±1% (@90-264VAC input, 0-100% load) |
| Output Rise Time | <2S @ nominal input (100% load) |
| Output Settling Time | >20ms @ 115VAC, >50 ms @ 230VAC (100% load) |
| Voltage Overshoot | ≤5.0% |
| Input | |
| Input Voltage Range | 90-264VAC |
| Rated Input Voltage Range | 100-240VAC |
| Frequency Range | 47Hz-63Hz |
| Rated Frequency | 50Hz/60Hz |
| Start-up Voltage | 90VAC |
| Efficiency | >90.0% @115VAC, >91.0% @ 230VAC |
| Input Current | <4.40A @115VAC, <2.20A @ 230VAC |
| Start-up Inrush Current | <35A @ 115VAC& 230VAC |
| Power Factor | >0.99 @ 115VAC, >0.93 @ 230VAC |
| Protection Function | |
| Over-power Protection | 288-360W swing test (Test method: Continuously increase the output current until protection is triggered; Protection mode: swing test; automatically resumes normal operation after the overpower condition is resolved.) |
| Over-voltage Protection | 28-29V swing test (Short pins 1 and 2 of U8 to trigger the swing test; output returns to normal when the short is removed). Note: Do not apply an external voltage |
| Over-current Protection | 12-15A swing test (Test method: Continuously increase the output current until protection is triggered; Protection mode: swing test; the unit automatically resumes normal operation once the overcurrent condition is resolved.) |
| Short-circuit Protection | Short-circuit the power supply's output terminals directly using a copper wire with sufficient cross-sectional area and a length of 15 cm ± 5 cm. The short-circuit may be maintained for an extended period; the unit automatically resumes normal operation once the short-circuit is resolved. |
| Operation Environment | |
| Operation TEMP/ Humidity | -40℃~+70℃, 20%-95%RH non-condensing |
| Storage TEMP/ Humidity | -40℃~+85℃, 10%-95%RH non-condensing |
| Temperature Coefficient | ±0.03%/℃ (0-50℃) |
| Vibration | Frequency range: 10-500 Hz, acceleration: 2 G, 10 minutes per sweep cycle, with 6 sweep cycles along each of the X, Y, and Z axes |
| Shock | Acceleration: 20 G, duration: 11 ms, with 3 shock tests along each of the X, Y, and Z axes |
| Altitude | 2000 m |
| Safety and EMC Standard | |
| Safety Standards | EN IEC 62368-1 ■Reference □Certification |
| Insulation Strength | Input-Output: 3 kV AC/10 mA; Input-Enclosure: 1.5 kV AC/10 mA; Output-Enclosure: 0.5 kV DC/10 mA. Each test lasts 1 minute |
| Grounding Test | Test conditions: 32 A for 2 minutes; ground impedance: <0.1 Ω. |
| Leakage Current | Input to ground ≤3.5 mA; input to output ≤0.25 mA (Input 264 VAC, frequency 63 Hz) |
| Insulation Resistance | Input-output: 10 MΩ |
| Electromagnetic Interference (EMI) | |
| Conducted Interference | EN55022, EN55024, FCC Part 15 Class B |
| Radiated Interference | EN55022, EN55024, FCC Part 15 Class B |
| Harmonic Current | EN61000-3-2 Class D |
| Conducted Immunity | EN61000-4-6 Level 3 |
| Radiated Immunity | EN61000-4-3 Level 3 Class B |
| Power-Frequency Immunity | EN61000-4-8 Level 3 |
| Electrostatic Immunity | EN61000-4-2 Level 4 Class B |
| Fast Pulse Groups | EN61000-4-4 Level 4 Class B |
| Lightning Strikes (Surge) | EN61000-4-5 Level 4 Class B |
| Interrupts, Dips | EN61000-4-11 |
| Others | |
| Dimension | 131*121*45mm |
| Net /Gross Weight | 0.74kg/ 0.78kg |
| Warranty | 5 years, lifelong maintenance |

- 90~264VAC input
- 100% full load aging test
- Meets safety and EMC standards
- High efficiency, long life, and high reliability
- Operating temperature range: -40℃~+70℃
- Protection functions: short circuit/overload/overvoltage
Factory automation, Industrial control systems, Electromechanical equipment, Semiconductor manufacturing equipment