Specifications
| Connection: | Plug In,Desktop | Output current: | 2.5A |
| Output voltage: | 52V | Power: | 130W |
| Ac plug: | Optional USA EU UK AU Type | Protection: | Short Circuit/Over Current/Over Voltage |
| Input voltage: | 90VAC~264VAC | Frequency range: | 47Hz~63Hz |
| Efficiency: | 91% | MTBF: | 100,000Hrs |
| High Light: | 130W Desktop Power Adapter,52V Desktop Power Supply,No Fan AC To DC Adapter |
||
Product Description
130W/52V Desktop Power Adapter
Product Features
- 2 years warranty
- 100% full load aging test
- Power Input: AC90~264V
- No fan, completely tranquil work
- Operation temperature: -20℃~65℃
- High efficiency, long life time and high reliability
- Support production for short circuit/over current/over voltage protection
Technical Specifications
| Model | GWS-AP130-52 |
|---|---|
| Output | |
| Group of Output | 1 |
| DC Voltage | 52VDC |
| Default Output Voltage | 0-2.5A |
| Ripple Noise: 0<Ta≤55℃ | ≤50mVp-p |
| Ripple Noise: -15≤Ta≤0℃ | ≤100mVp-p |
| Stabilized Voltage Precision | ±1% |
| Line Regulation | ±1% |
| Load Regulation | ±1% |
| Temperature Coefficient | ±0.03%/℃ |
| Output Start Time | ≤3.0S (120Vac input, Full load), ≤2.0S (220Vac input, full load) |
| Output Hold Time | ≥10mS(120Vac input, Full load), ≥20mS(220Vac input, full load) |
| Voltage Overshoot | <5.0% |
| Input | |
| Input Voltage Range | 90VAC~264VAC |
| Input Rated Voltage Range | 100VAC~240VAC |
| Frequency Range | 47Hz~63Hz |
| Efficiency | 91% |
| Input Current | <1.1A |
| Inrush Starting Current | <40A@300Vac cold start |
| Leakage Current | Input to output≤ 0.25mA |
| Output Protection | |
| Over Power | 156W-195W swing machine |
| Over Voltage | 59-60V swing machine |
| Over Current | 3-3.75A swing machine |
| Short Circuit | It can be short circuited for a long time and automatically recover after the short circuit is eliminated. |
| Operation Environment | |
| Operation TEMP/Humidity | -20℃~65℃, 20%~90%RH |
| Storage TEMP/Humidity | -40℃~85℃, 5%~95%RH Non condensing |
| Safety and EMC Standard | |
| Security Standard | EN62368-1 |
| Dielectric Strength | Input-output: 3KVac/10mA, Input-Earth: 1.5 KVac/10mA, Output-Earth: 0.5 KVDC/10mA, Test time is 1min |
| Insulation Resistance | Input-Output: 100M ohms, Input-Case: 100M ohms, Output-Case: 100M ohms |
| Electromagnetic Interference | EN55022 Class A |
| Harmaonic Current | IEC61000-3-2 class A equipment requirements |
| EMI | EN61000-4-2,4,5,6,8,11 ENV50204 |
| Others | |
| MTBF | 100,000Hrs AT 25℃, MIL-217 method 2 components stress method |
| Dimension | 172*72*34mm |
Notes: If the specification is not specified, all specifications and parameters shall be measured at rated input, rated load and 25℃ ambient temperature. Ripple noise test method: the use of a 12# twisted pair, while the terminal to parallel capacitance of 0.1uF and 10uF, measured at the scope of the oscilloscope 20MHz bandwidth. The power supply will be installed on the final equipment as a component, and the final equipment will still have to meet the EMC condition.
Dimensions