65W 24VDC AC DC Desktop Adapter No Fan Design High Efficiency Power Supply Adapter
Basic Properties
Place of Origin:
China
Brand Name:
GWSpower
Certification:
CE, FCC, RoHS
Model Number:
GWS-AP65-24
Trading Properties
Minimum Order Quantity:
1
Payment Terms:
T/T,Western Union
Supply Ability:
500000pcs/month
Specifications
| Output Current: | 0-2.7A | Input Voltage: | 90VAC~264VAC |
| Ripple Noise: | ≤50mVp-p (0| Frequency Range: |
47Hz~63Hz |
|
| Efficiency: | 87% | Output Voltage: | 24VDC |
| High Light: | 65W AC DC Desktop Adapter,24V Desktop Power Supply,No Fan Desktop Power Supply Adapters |
||
Product Description
65W/24V Desktop Power Adapter
Key Features
- 100% full-load aging test
- Input voltage: 200VAC-264VAC
- Fanless, completely quiet operation
- High efficiency, long life and high reliability
- Operating temperature range: -20℃~+65℃
- Protection function: short-circuit/overload/overvoltage
Technical Specifications
| Model | GWS-AP65-24 |
|---|---|
| Output | |
| No. of Output Group | 1 |
| DC Voltage | 24VDC |
| Output Current Range | 0-2.7A |
| Ripple Noise: 0℃<Ta≤55℃ | ≤50mVp-p |
| Ripple Noise: -15℃≤Ta≤0℃ | ≤100mVp-p |
| Stabilized Voltage Precision | ±1% |
| Line Regulation | ±1% |
| Load Regulation | ±1% |
| Temperature Coefficient | ±0.03%/℃ |
| Output Start-up Time | ≤3.0S (120VAC input, full load), ≤2.0S (220VAC input, full load) |
| Output Hold-up Time | ≥10mS (120VAC input, full load), ≥20mS (220VAC input, full load) |
| Voltage Overshoot | <5.0% |
| Input | |
| Input Voltage Range | 90VAC~264VAC |
| Input Rated Voltage Range | 100VAC~240VAC |
| Frequency Range | 47Hz~63Hz |
| Efficiency | 87% |
| Input Current | <0.7A |
| Inrush Starting Current | <40A@300VAC cold start |
| Leakage Current | Input to output≤ 0.25mA |
| Output Protection | |
| Overpower Protection | 54W-97.5W down |
| Overvoltage Protection | 28V-29V down |
| Overcurrent Protection | 3.25A-4.05A down |
| Short-circuit Protection | Sustainable for prolonged short circuits, automatically recovers after the short circuit is cleared. |
| Operation Environment | |
| Operation TEMP/ Humidity | -20℃~65℃, 20%~90%RH |
| Storage TEMP/ Humidity | -40℃~85℃, 5%~95%RH Non-condensing |
| Safety and EMC Standard | |
| Safety Standard | GB4943/EN62368 |
| Insulation Strength | Input-Output: 3KVac/10mA; Input-Ground: 1.5KVac/10mA; Output-Ground: 0.5KVDC/10mA; Test time: 1min |
| Insulation Impedance | Input-Output: 100M ohms; Input-Enclosure: 100M ohms; Output-Enclosure: 100M ohms |
| Electromagnetic Interference | EN55022 Class A |
| Harmonic Current | IEC61000-3-2 Class A equipment requirements |
| Electromagnetic Immunity | EN61000-4-2, 4,5,6,8,11 ENV50204, Class A heavy industry standard |
| Others | |
| MTBF | 100,000Hrs at 25℃, MIL-217 Method 2 components stress method |
| Dimension | 125*51*32mm |
| Net Weight | 0.195kg |
| Warranty | 2 years, lifelong maintenance |
Dimensions

All specifications were measured at rated input, rated load, and 25°C ambient temperature. Ripple noise test method: Use a 12# twisted-pair cable, with 0.1uF and 10uF capacitors connected in parallel at the termination. Measure using an oscilloscope with a 20MHz bandwidth. The power supply will be installed as a component in the final device, which must still meet EMC requirements.