52VDC Fanless High Efficiency Desktop Power Adapter AC DC Power Supply with 250W Output
Basic Properties
Place of Origin:
China
Brand Name:
GWSpower
Certification:
CE, FCC, RoHS
Model Number:
GWS-AP250-52
Trading Properties
Minimum Order Quantity:
1
Payment Terms:
T/T,Western Union
Supply Ability:
500000pcs/month
Specifications
| Output Voltage: | 52VDC | Output Current: | 0-4.5A |
| Input Voltage: | 200VAC~264VAC | Frequency Range: | 47Hz~63Hz |
| Efficiency: | 89% | Insulation Strength: | Input-Output: 3KVac/10mA |
Product Description
250W/52V Desktop Power Adapter
Product Features
- 100% full-load aging test
- Input voltage: 200VAC-264VAC
- Fanless, completely quiet operation
- High efficiency, long life and high reliability
- Operating temperature range: -20℃~+65℃
- Protection function: short-circuit/overload/overvoltage
Technical Specifications
| Model | GWS-AP250-52 |
|---|---|
| Output | |
| No. of Output Group | 1 |
| DC Voltage | 52VDC |
| Output Current Range | 0-4.5A |
| Ripple Noise | <300mVp-p (Vin 240Vac/50Hz full load) |
| Voltage Regulation Accuracy | ±3% |
| Source Regulation | ±1% |
| Load Regulation | ±3% |
| Temperature Coefficient | ±0.03%/℃ |
| Output Start-up Time | ≤2.0S (220VAC input, full load) |
| Output Hold-up Time | ≥20mS (The power shall support 4.95A at 200-240VAC and 25℃) |
| Voltage Overshoot | <5.0% |
| Input | |
| Input Voltage Range | 200VAC~264VAC |
| Rated Input Voltage Range | 200VAC~240VAC |
| Frequency Range | 47Hz~63Hz |
| Efficiency | 89% |
| Input Current | <2.2A |
| Start-up Inrush Current | <40A@300VAC cold start |
| Leakage Current | Input to output ≤ 0.25mA |
| Protection Function | |
| Overpower Protection | 290W~360W down |
| Overvoltage Protection | 59V~60V down |
| Overcurrent Protection | 6A~6.6A down |
| Short-circuit Protection | Sustainable for prolonged short circuits; automatically recovers after the short circuit is cleared. |
| Operation Environment | |
| Operation TEMP/ Humidity | -20℃~+65℃, 20%-90%RH non-condensing |
| Storage TEMP/ Humidity | -20℃~+80℃, 5%-90%RH non-condensing |
| Safety and EMC Standard | |
| Safety Standard | GB4943/EN62368 |
| Insulation Strength | Input-Output: 3KVac/10mA; Input-Ground: 1.5KVac/10mA; Output-Ground: 0.5KVDC/10mA; Test time: 1min |
| Insulation Impedance | Input-Output: 100M ohms; Input-Enclosure: 100M ohms; Output-Enclosure: 100M ohms |
| Electromagnetic Interference | EN55022 Class A |
| Harmonic Current | IEC61000-3-2 Class A equipment requirements |
| Electromagnetic Immunity | EN61000-4-2, 4,5,6,8,11 ENV50204, Class A heavy industry standard |
| Others | |
| MTBF | 100,000Hrs at 25℃, MIL-227 Method 2 components stress method |
| Dimension | 186*80*40mm |
| Net/Gross Weight | 1.19kg/ 1.28kg |
| Warranty | 2 years, lifelong maintenance |
All specifications were measured at rated input, rated load, and 25°C ambient temperature. Ripple noise test method: Use a 12# twisted-pair cable, with 0.1uF and 10uF capacitors connected in parallel at the termination. Measure using an oscilloscope with a 20MHz bandwidth. The power supply will be installed as a component in the final device, which must still meet EMC requirements.
Dimensions