60W 48V DIN Rail Industrial Power Supply With Flame Retardant Plastic Housing
| Output Voltage: | 48VDC | Output Current: | 1.25A |
| Output Power: | 60W | Peak Power: | 90W |
| Input Voltage: | 90-264VAC | Frequency Range: | 47Hz-63Hz |
| Efficiency: | >89.0%@ 230VAC | Operation Temperature: | -40℃~+70℃ |
| Dimension: | 102.5*93*41mm | Net Weight: | 0.28kg |
| High Light: | 48V DIN Rail Industrial Power Supply,60W DIN Rail Power Supply |
||
The GWS-DP60-48 is an economical 60W DIN rail industrial power supply conforming to German industrial standards. Suitable for installation on TS-35/7.5 or TS-35/15 rails, it features a full-range AC input from 90Vac to 264Vac and complies with EN61000-3-2 standards for EU-specified harmonic current specifications.
This power supply utilizes a highly flame-retardant plastic housing, ensuring safety, robustness, and durability. Based on natural air convection principles, the housing features numerous ventilation holes at the bottom and top to facilitate internal airflow, achieving a high conversion efficiency of 89%. This design extends the power supply's lifespan and enables reliable operation in harsh environments from -40°C to +70°C.
The unit includes comprehensive protection features including short-circuit, overcurrent, and overvoltage protection, making it suitable for a wide variety of inductive or capacitive load applications. Its robust protection functions and compliance with relevant industrial control equipment certifications make it a highly competitive power supply solution for industrial applications.
| Model | GWS-DP60-48 |
|---|---|
| Output | |
| Group of Output | 1 |
| Rated Output Voltage | 48VDC |
| Factory Set Output Voltage | 48.00-48.2VDC (Vin: 220Vac / Load: 0A) |
| Output Rated Current | 1.25A |
| Output Current Range | 0-1.25A |
| Rated Output Power | 60W |
| Total Peak Output Power | 90W (sustainable time 10S/220VAC) |
| Peak Output Current | 1.5A (sustainable time 10S/220VAC) |
| Ripple Noise | Peak-to-peak value ≤100mV. (Measurement method: The terminal should be connected in parallel with 0.1uF and 47uF capacitors, and the measurement should be performed at a bandwidth of 20MHz) |
| Output Voltage Range | 47-56VDC |
| Stabilized Voltage Precision | ±1% (48.48VDC-47.52VDC) |
| Line Regulation | ±0.5% (48.24VDC-47.76VDC), (@85-264VAC input, 100% load) |
| Load Regulation | ±1% (48.48V-47.52V), (@85-264Vac input, 0-100% load) |
| Output Start-up Time | <1.5S @ nominal input (100% load) |
| Output Hold-up Time | >20ms @ 115VAC, >1250ms @ 230VAC (100% load) |
| Voltage Overshoot | ≤5.0% |
| Input | |
| Input Voltage Range | 90-264VAC |
| Rated Input Voltage Range | 100-240VAC |
| Frequency Range | 47Hz-63Hz |
| Rated Frequency | 50Hz/60Hz |
| Starting Voltage | 90VAC |
| Efficiency | >85.0%@115VAC, >89.0%@ 230VAC |
| Input Current | <1.40A@115VAC, <0.80A@ 230VAC |
| Start Inrush Current | <20A@ 115VAC, <35A@230VAC |
| Power Factor | PF>0.6 (at full load) |
| Protection | |
| Output Overpower Protection | 78-97W swing machine |
| Output Overvoltage Protection | 57-70V swing machine |
| Output Overcurrent Protection | 1.5-1.875A swing machine |
| Output Short Circuit Protection | Use a copper wire with a sufficient cross-sectional area and a length of 15cm±5cm to directly short-circuit at the power output port, which can be short-circuited for a long time, and can be automatically restored after the short-circuit is eliminated. |
| Operation Environment | |
| Operation TEMP / Humidity | -40℃~+70℃, 20%-95%RH non-condensing |
| Storage TEMP / Humidity | -40℃~+85℃, 10%-95%RH non-condensing |
| Temperature Coefficient | ±0.03%/℃ (0-50℃) |
| Vibration | Frequency range 10-500Hz, acceleration 2G, each sweep cycle 10min. 6 sweep cycles along the X, Y, and Z axes |
| Impact | Acceleration 20G, duration 11ms, 3 shocks along X, Y, and Z axis each |
| Altitude | 2000m |
| Safety and Electromagnetic Compatibility Standard | |
| Security Standard | GB4943/EN62368-1 |
| Dielectric Strength | Input-Output: 3KVAC/10mA, Input-Case:1.5KVAC/10mA Output-Case: 0.5KVDC/10mA , Time for each testing is 1min. |
| Ground Test | Test conditions: 32A/2 minutes, Ground impedance: <0.1 ohms. |
| Leakage Current | Input to ground ≤3.5mA, Input to output ≤0.25mA (Input 264VAC, frequency 63Hz) |
| Insulation Resistance | Input-Output: 10M ohms |
| Conducted Disturbance | EN55022, EN55024, FCC PART 15 Class B |
| Radiated Interference | EN55022, EN55024, FCC PART 15 Class B |
| Harmonic Current | EN61000-3-2 Class D |
| Conducted Disturbance | EN61000-4-6 Level 3 |
| Radiation Harassment | EN61000-4-3 Level 3 Class B |
| Power Frequency Harassment | EN61000-4-8 Level 3 |
| Static Harassment | EN61000-4-2 Level 4 Class B |
| Fast Burst | EN61000-4-4 Level 4 Class B |
| Lightning Strike (Surge) | EN61000-4-5 Level 4 Class B |
| Interrupted Fall | EN61000-4-11 |
| Others | |
| Dimension | 102.5*93*41mm |
| Net /Gross Weight | 0.28kg/ 0.32kg |
| Warranty | 5 years, lifelong maintenance |
- 90~264VAC input
- 100% full load aging test
- Meets safety EMC standards
- High efficiency, long life, and high reliability
- Operating temperature range: -40℃~+70℃
- Protection functions: short circuit/overload/overvoltage
- Factory automation
- Industrial control systems
- Electromechanical equipment
- Semiconductor manufacturing equipment