8 Port Gigabit Managed Industrial Ethernet Switch Fanless Cooling DIN Rail Mounting
| Fixed Port: | 4*10/100/1000Base-T RJ45 Ports (Data) 4*100/1000Base-X Uplink SFP Fiber Ports (Data) | Twisted Pair Transmission: | 10BASE-T: Cat3,4,5 UTP (≤100 Meters) 100BASE-TX: Cat5 Or Later UTP (≤100 Meters) 1000BASE-T: Cat5e Or Later UTP (≤100 Meters) |
| Optical Cable Distance: | Multi-mode: 850nm/ 0-550m, Single-mode: 1310nm/ 0-40km, 1550nm/ 0-120km | Switching Capacity: | 56Gbps (non-blocking) |
| Forwarding Rate: | 11.9Mpps @64byte | Power Consumption: | Standby<6W, Full Load<15W |
| Input Voltage: | DC12-57V, 5P Industrial Phoenix Terminal, Support Reverse Connection Protection | Operation Temperature: | -40~+80°C, 5%~90% RH Non-condensing |
| Dimension: | 145*134.5*47mm | Net Weight: | 0.75kg |
| High Light: | 8 Port Easy Managed Industrial Switch,Fanless Cooling Managed Industrial Switch,Gigabit Industrial Ethernet Switch DIN Rail |
||
The ONV-IPS53084FM is a Gigabit Easy managed industrial Ethernet fiber switch independently developed by ONV. It features 4×10/100/1000Base-T adaptive RJ45 ports and 4×100/1000Base-X uplink SFP fiber ports, with each port supporting wire-speed forwarding.
The ONV-IPS53084FM supports Web management, ONV-NMS management platform, and mobile APP cloud platform management, enabling functions such as security network topology management, link aggregation, port management, port mirroring, and remote operation and maintenance. With high reliability, easy installation and maintenance, fast switching function, and multiple access ports, it is suitable for LAN device access of various scales. Ideal for intelligent transportation, rail transportation, electric power industry, mining, petroleum, shipping, metallurgy, green energy construction, and other industrial scenarios to build economical, efficient, stable, and reliable communication networks.
| Model | ONV-IPS53084FM |
|---|---|
| Interface Characteristics | |
| Fixed Port | 4×10/100/1000Base-T RJ45 ports (Data) 4×100/1000Base-X uplink SFP fiber ports (Data) 2 sets V+, V- redundant DC power port (5P phoenix terminal) |
| Ethernet Port | Port 1-4 can support 10/100/1000Base-T auto-sensing, full/half duplex MDI/MDI-X self-adaption |
| Twisted Pair Transmission | 10BASE-T: Cat3,4,5 UTP (≤100 meters) 100BASE-TX: Cat5 or later UTP (≤100 meters) 1000BASE-T: Cat5e or later UTP (≤100 meters) |
| Optical Fiber Port | Gigabit optical fiber interface, default no include optical module (optional single-mode/multi-mode, single fiber/dual fiber optical module. LC) |
| Optical Cable/Distance | Multi-mode: 850nm/0-550m Single-mode: 1310nm/0-40km, 1550nm/0-120km |
| Chip Parameter | |
| Network Management Type | L2 |
| Network Protocol | IEEE802.3 10BASE-T, IEEE802.3i 10Base-T, IEEE802.3u 100Base-TX, IEEE802.3ab 1000Base-T, IEEE802.3z 1000Base-X, IEEE802.3x |
| Forwarding Mode | Store and forward (Full wire-speed) |
| Switching Capacity | 56Gbps (non-blocking) |
| Forwarding Rate@64byte | 11.9Mpps |
| MAC | 8K |
| Buffer Memory | 4.1M |
| Jumbo Frame | 10K |
| LED Indicator | Power/System: SYS (Green), Fiber port: L/A (Green), Network: Link (Yellow) |
| Reset Switch | Press for 6 seconds and then release to restore to factory settings Short press twice (1 second interval) to switch to unmanaged state |
| Power Supply | |
| Power Consumption | Standby<6W, full load<15W |
| Input Voltage/Interface | DC12-57V, 5P industrial Phoenix terminal, support reverse connection protection |
| Power Supply | No, optional 12V/24W or 24V/24W industrial power supply |
| Physical Parameter | |
| Operation Temp/Humidity | -40~+80°C, 5%~90% RH non-condensing |
| Storage Temp/Humidity | -40~+85°C, 5%~95% RH non-condensing |
| Dimension (L×W×H) | 145×134.5×47mm |
| Net/Gross Weight | 0.75kg / 1.0kg |
| Installation | Desktop, 35mm DIN Rail |
| Certification & Warranty | |
| Lightning Protection | Protection level: IP40 Lightning protection: 6KV 8/20us IEC61000-4-3 (RS):10V/m (80~1000MHz) FCC Part 15/CISPR22 (EN55022): Class A IEC61000-6-2 (Common Industrial Standard) IEC61000-4-9 (Pulsed magnet field): 1000A/m IEC61000-4-10 (Damped oscillation): 30A/m, 1MHz IEC61000-4-12/18 (Shockwave): CM 2.5kV, DM 1kV IEC61000-4-4(EFT): Power cable:±4kV, Data cable: ±2kV IEC61000-4-16 (Common-mode transmission): 30V, 300V, 1s IEC61000-4-2 (ESD): ±8kV contact discharge, ±15kV air discharge IEC61000-4-6 (Radio frequency transmission): 10V(150kHz~80MHz) IEC61000-4-8 (Power frequency magnetic field):100A/m, 1000A/m, 1s-3s IEC61000-4-5 (Surge): Power cable: CM±4kV/ DM±2kV, Data cable: ±4kV |
| Mechanical Properties | IEC60068-2-6 (Anti Vibration), IEC60068-2-32 (Free Fall), IEC60068-2-27 (Anti Shock) |
| Certification | CE mark, commercial, CE/LVD EN62368-1, FCC Part 15 Class A, RoHS |
| Warranty | 5 years, lifelong maintenance |
| Network Management Feature | |
| Interface | Port status display, Port traffic statistics Port duplex/negotiation rate configuration EEE Energy-saving and green Ethernet function IEEE802.3x flow control configuration (Full-duplex) |
| VLAN | Port-based IEEE802.1Q VLAN configuration (4K) |
| Port Mirroring | Bidirectional data mirroring based on port |
| Security | Broadcast storm control, Port isolation, Port speed limit |
| Management | Web Management, One-Click Restore, Add User Account Web Firmware Upgrade, Configuration Backup and Restore |
| System | Web browser: Mozilla Firefox 2.5 or higher, Google browser chrome V42 or higher Category 5 and above Ethernet cables TCP/IP, network adapter, and network operating systems (Such as Linux or Mac OS X) are installed on each computer in the network with Category 5 and above Ethernet cables |

- Support non-blocking wire-speed forwarding
- Support full-duplex based on IEEE802.3x and half-duplex based on Backpressure
- Support Gigabit RJ45 port and SFP fiber port combination, which enables users to flexibly build networking to meet the needs of various scenarios
- Support remote upgrades, remote reboots, and factory resets
- Support real-time fault alarms, fault location, and automatic work order dispatch
- Cloud platform + mobile app operation and maintenance management: visualized port control, network topology management, and VLAN segmentation
- Web-based network management functions: QoS, link aggregation, ring network management, port mirroring, port control, and bandwidth management
- Practical network management functions are retained according to industry application requirements, and network deployment and centralized operation and maintenance can be quickly realized through the operation and maintenance platform
- CE, FCC, RoHS certifications
- User-friendly panel can show the device status through the LED indicator of PWR, Link, and L/A
- Low power consumption, Aluminum alloy housing, and excellent heat dissipation to ensure the stable operation of the switch
| Model | Description | Recommended Power Supply |
|---|---|---|
| ONV-IPS53084FM | L2 Easy managed industrial Ethernet fiber switch with 4×10/100/1000M RJ45 ports and 4×100/1000M uplink SFP fiber ports. It can support dual DC power supply input and DIN Rail mounting. | 24W |
Note: The optical module and power supply are not included and need to be purchased.
| Packing List | Qty | Unit |
|---|---|---|
| 8-port gigabit Easy managed industrial Ethernet switch | 1 | Set |
| User Guide | 1 | PC |
| Warranty Card and Certificate of Conformity | 1 | PC |
| Product | Model | Description | Unit |
|---|---|---|---|
| 1.25G Optical Module | 2630-G | Industrial SFP optical module, 1.25G multi-mode dual fiber 850nm, transmission distance: 550m, LC interface. supports DDM function and hot plugging. | PC |
| 2632-G | Industrial SFP optical module, 1.25G single-mode dual fiber 1310nm, transmission distance: 20km, LC interface. supports DDM function and hot plugging. | PC | |
| 2612-T-G | Industrial SFP optical module, 1.25G single-mode single fiber TX1310nm/ RX1550nm, transmission distance: 20km, LC interface. supports DDM function and hot plugging. | PC | |
| 2613-R-G | Industrial SFP optical module, 1.25G single-mode single fiber TX1550nm/ RX1310nm, transmission distance: 20km, LC interface. supports DDM function and hot plugging. | PC | |
| 2612-T-SC-G | Industrial SFP optical module, 1.25G single-mode single fiber TX1310nm/ RX1550nm, transmission distance: 20km, SC interface. supports DDM function and hot plugging. | PC | |
| 2613-R-SC-G | Industrial SFP optical module, 1.25G single-mode single fiber TX1550nm/ RX1310nm, transmission distance: 20km, SC interface. supports DDM function and hot plugging. | PC |
| Product | Model | Description | Unit |
|---|---|---|---|
| 24W DIN Rail Industrial Power Supply | GWS-DP24-12 | DIN Rail 24W single set of output power supply Input Voltage: AC100V~240V 50-60H, 0.35A Output Voltage: DC12V, 2.0A Operation Temperature: -40℃ to +70℃ |
PC |
| 24W DIN Rail Industrial Power Supply | GWS-DP24-24 | DIN Rail 24W single set of output power supply Input Voltage: AC100V~240V 50-60H, 0.35A Output Voltage: DC24V, 1.0A Operation Temperature: -40℃ to +70℃ |
PC |
| Model | Description |
|---|---|
| ONV-IPS53064FGM | L2 Easy managed industrial Ethernet fiber switch with 5×10/100/1000M RJ45 ports and 1×100/1000M uplink SFP fiber port. It can support dual DC power supply input and DIN Rail mounting. |
| ONV-IPS53064FM | L2 Easy managed industrial Ethernet fiber switch with 4×10/100/1000M RJ45 ports and 2×100/1000M uplink SFP fiber ports. It can support dual DC power supply input and DIN Rail mounting. |
| ONV-IPS53008M | L2 Easy managed industrial Ethernet switch with 8×10/100/1000M RJ45 ports. It can support dual DC power supply input and DIN Rail mounting. |
| ONV-IPS53108FM | L2 Easy managed industrial Ethernet fiber switch with 8×10/100/1000M RJ45 ports and 2×100/1000M uplink SFP fiber ports. It can support dual DC power supply input and DIN Rail mounting. |
