24W 24VDC DIN Rail Industrial Power Supply Metal Shell Design EMC Standard
| Output Voltage: | 24VDC | Output Current: | 1.0A |
| Output Power: | 24W | Peak Power: | 36W |
| Input Voltage: | 90-264VAC | Frequency Range: | 47Hz-63Hz |
| Efficiency: | >85.0% @115VAC, >84.0% @230VAC | Operating Temperature: | -40℃ To 70℃ |
| Dimensions: | 103*82.5*23mm | Ripple Noise: | ≤100mV Peak-to-peak |
| High Light: | DIN Rail Industrial Power Supply,Din Rail Mount 24vdc Power Supply,EMC Standard Din Rail Power Supply |
||
24W/24V DIN Rail Industrial Power Supply
Overview
The GWS-DP24-24 is an economical 24W DIN rail power supply that conforms to German industrial standards. Suitable for installation on TS-35/7.5 or TS-35/15 rails, it operates with 90VAC to 264VAC input and complies with EN61000-3-2 Standard on Harmonic Current Specifications specified by the European Union.
Featuring a metal shell design for improved heat dissipation, the GWS-DP24-24 achieves working efficiency up to 89% and operates in ambient temperatures from -40°C to 70°C with air circulation. It includes constant current mode overload protection, making it suitable for various inductive or capacitive load applications. With complete protection functions and compliance with relevant industrial control equipment certifications, this power supply offers a highly competitive solution for industrial applications.
Technical Specifications
Output
| Specification | Value |
|---|---|
| Group of Output | 1 |
| DC Voltage | 24VDC |
| Default Output Voltage | 24.00-24.2VDC (Vin: 220VAC/ Load: 0A) |
| Output Rated Current | 1.0A |
| Output Current Range | 0-1.0A |
| Rated Output Power | 24W |
| Total Peak Output Power | 36W (sustainable time 10S/220VAC) |
| Peak Output Current | 1.5A (sustainable time 10S/220VAC) |
| Ripple Noise | Peak-to-peak value ≤100mV. (Measurement method: The terminal should be connected in parallel with 0.1uF and 47uF capacitors, and the measurement should be performed at a bandwidth of 20MHz) |
| Output Voltage Range | 22.5-28VDC |
| Stabilized Voltage Precision | ±1% (@ 90-264VAC input, 100% load) |
| Line Regulation | ±0.5% (@ 90-264VAC input, 100% load) |
| Load Regulation | ±1% (@90-264VAC input, 0-100% load) |
| Output Start Time | <3S @115VAC, <1.6S@230VAC (100% load) |
| Output Hold Time | >20ms @230VAC (100% load) |
| Voltage Overshoot | ≤5.0% |
Input
| Specification | Value |
|---|---|
| Input Voltage Range | 90-264VAC |
| Input Rated Voltage Range | 100-240VAC |
| Frequency Range | 47Hz-63Hz |
| Rated Frequency | 50Hz/60Hz |
| Starting Voltage | 90VAC |
| Efficiency | >85.0% @115VAC, >84.0% @ 230VAC |
| Input Current | <0.60A @115VAC, <0.30A @ 230VAC |
| Start Inrush Current | <60A @ 230VAC |
| Power Factor | PF>0.6 (at full load) |
Protection
| Specification | Value |
|---|---|
| Output Over Power | 28.8-36W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode: Swing machine, Self-recovery after over-power released.) |
| Output Over Voltage | 28-30V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage. |
| Output Over Current | 1.2-1.5A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode: Swing machine, Self-recovery after over-current released.) |
| Output Short Circuit | Use a copper wire with a sufficient cross-sectional area and a length of 15cm±5cm to directly short-circuit at the power output port, which can be short-circuited for a long time, and can be automatically restored after the short-circuit is eliminated. |
Operation Environment
| Specification | Value |
|---|---|
| Operation TEMP/ Humidity | -40℃-70℃, 20%-95%RH non-condensing |
| Storage TEMP/ Humidity | -40℃-85℃, 10%-95%RH non-condensing |
| Temperature Coefficient | ±0.03%/℃ (0-50℃) |
| Vibration | Frequency range 10-500Hz, acceleration 2G, each sweep cycle 10min. 6 sweep cycles along the X, Y, and Z axes |
| Impact | Acceleration 20G, duration 11ms, 3 shocks along X, Y, and Z axis each |
| Altitude | 2000m |
Safety and Electromagnetic Compatibility Standard
| Specification | Value |
|---|---|
| Security Standard | GB4943/EN62368-1 ■Reference □Certification |
| Dielectric Strength | Input-Output: 3KVAC/10mA, Input-Case:1.5KVAC/10mA Output-Case: 0.5KVDC/10mA , Time for each testing is 1min. |
| Ground Test | Test conditions: 32A/2 minutes, Ground impedance: <0.1 ohms. |
| Leakage Current | Input to ground ≤3.5mA, Input to output ≤0.25mA (Input 264VAC, Frequency 63Hz) |
| Insulation Resistance | Input-Output: 10M ohms |
| EMI Conducted Interference | EN55022, EN55024, FCC PART 15 CLASS B |
| EMI Radiated Interference | EN55022, EN55024, FCC PART 15 CLASS B |
| Harmonic current | EN61000-3-2 CLASS D |
| EMS Conducted Emission | EN61000-4-6 Level3 |
| EMS Radiated Emission | EN61000-4-3 Level3 criterion B |
| EMS Power Frequency Emission | EN61000-4-8 Level3 |
| EMS Electrostatic Emission | EN61000-4-2 Level4 criterion B |
| EMS EFT | EN61000-4-4 Level4 criterion B |
| EMS Surge | EN61000-4-5 Level4 criterion B |
| EMS Dip and Interruption | EN61000-4-11 |
Others
| Specification | Value |
|---|---|
| Dimension | 103*82.5*23mm |
| Warranty | 5 years |
Key Features
- Meets EMC Standard
- 100% full load aging test
- Power Input: AC90-264V
- Wide operation temperature range: -40℃ to 70℃
- High efficiency, long lifetime, and high reliability
- Protection against short circuit, over current, and over voltage
Applications
- Factory automation
- Industrial Control System
- Electro-mechanical apparatus
- Semiconductor fabrication equipment
Dimensions