60W 12V DC Industrial DIN Rail Power Supply with Wide Operation Temperature Range

Properti Dasar
Tempat Asal: Cina
Nama merek: GWSpower
Sertifikasi: CE, FCC, RoHS
Nomor Model: GWS-DP60-12
Properti Perdagangan
Jumlah pesanan minimum: 1
Ketentuan Pembayaran: T/T, Western Union
Kemampuan Penyediaan: 500000 buah/bulan
Spesifikasi
Output Voltage: 12VDC Output Current: 5a
Output Power: 60W Peak Power: 80W
Input Voltage: 90~264VAC Frequency Range: 47Hz ~ 63Hz
Efficiency: >85,0% @115Vac, >88% @230Vac Operation Temperature: -40℃-70℃
Storage Temperature: -40℃-85℃ Dimension: 102.5*93*41mm
High Light:

60W Industrial DIN Rail Power Supply

,

12V DC Din Rail Mounted Power Supply

,

60W Din Rail Power Supply 12vdc

Deskripsi Produk

60W/12V DIN Rail Industrial Power Supply

Overview

GWS-DP60-12 is an economical slim 60W DIN Rail industrial power supply series designed for installation on TS-35/7.5 or TS-35/15 mounting rails. The series features full-range AC input from 90VAC to 264VAC and complies with EN61000-3-2, the European Union standard for harmonic current regulation.

Constructed with a metal housing that enhances power dissipation, the GWS-DP60-12 achieves up to 89% efficiency and operates within an ambient temperature range of -40℃ to 70℃ under air convection. Equipped with a constant current mode for overload protection, it is suitable for various inductive or capacitive applications. Comprehensive protection functions and relevant industrial control certifications make the GWS-DP60-12 a highly competitive power supply solution for industrial applications.

Technical Specifications

Model: GWS-DP60-12
Output
Group of Output 1
DC Voltage 12V DC
Output Voltage Factory Setting 11.4-12.6VDC (Vin: 220Vac / LOAD: 0A)
Output Rated Current 5A
Output Current Range 0-5A
Output Rated Power 60W
Total Peak Output Power Up to 80W (Sustainable time 10S/220VAC)
Peak Output Current 6.66A (Sustainable time 10S/220VAC)
Ripple noise Peak-Peak ≤100mV (Test Method: The terminal shall be in parallel with capacitance of 0.1uF and 47uF, testing at 20MHz)
Output Regulation Range DC11.8~14.2V
Stabilized Voltage Precision ±5% (12.4Vdc-12.6Vdc)
Line Regulation ±1% (@90-264Vac input, 0-100% load)
Load Regulation ±5% (@90-264Vac input, 0-100% load)
Output Start Time <3.0S @ nominal input (100% load)
Output Hold Time >20ms @115Vac, >100 ms @ 230Vac (100% load)
Voltage Overshoot ≤10%
Input
Input Voltage Range 90~264VAC
Input Rated Voltage Range 100~240VAC
Frequency Range 47Hz~63Hz
Rated Frequency 50/60Hz
Starting Voltage 90VAC
Efficiency > 85.0% @ 115Vac, > 88% @ 230Vac
Input Current <1.60A @ 115Vac, < 0.80A @ 230Vac
Startup Impulse Current <40A @ 115Vac, <50A @ 230Vac
Power Factor PF>0.5 (at full load)
Protection
Output Overpower 78~97W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode: Swing machine, Self-recovery after over-power released.)
Output Overvoltage 18~24V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit). Note: Do not use external voltage.
Output Overcurrent 6.0~8.5A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode: Swing machine, Self-recovery after over-current released.)
Output Short circuit It achieves the long-term short circuit by connecting a sufficient cross-sectional area copper cable (Length at 15cm±5cm) with the power output port. Self-recovery to normal after removing the short circuit.
Operation Environment
Operation TEMP/ Humidity -40℃-70℃, 20%-95%RH
Storage TEMP/ Humidity -40℃-85℃, 10%-95%RH non-condensing
Temperature Coefficient ±0.03%/℃ (0-50℃)
Libration Frequency range: 10~500Hz, Acceleration: 2G, Each sweep cycle 10min. Six sweeps along the X, Y, and Z axes
Surge Acceleration: 20G, Duration time: 11mS, Three shocks along X, Y, and Z axes
Altitude 5000m
Safety and EMC Standard @25℃
Security Standard EN62368-1
Dielectric Strength Input-Output: 3KVAC/10mA, Input-Case:1.5KVAC/10mA. Output-Case:0.5KVDC/10mA, Time for each testing is 1min.
Grounding Test Test Condition: 32A/2min, Ground bond: <0.1 ohms.
Leakage Current Input to GND≤3.5mA, Input to output ≤0.25mA (Input 264Vac, 63Hz)
Insulation Resistance Input-Output: 10M ohms
EMI Conducted Interference EN55032, FCC PART 15 CLASS B
EMI Radiated Interference EN55032, FCC PART 15 CLASS B
Harmonic Current EN61000-3-2 CLASS D
EMS Conducted Emission EN61000-4-6 Level3
EMS Radiated Emission EN61000-4-3 Leve3 criterion B
EMS Power Frequency Emission EN61000-4-8 Level3
EMS Electrostatic Emission EN61000-4-2 Level4 criterion B
EMS EFT EN61000-4-4 Level4 criterion B
EMS Surge EN61000-4-5 Level4 criterion B
EMS Dip and Interruption EN61000-4-11
Others
Dimension 102.5*93*41mm
Warranty 5 years

Features

  • Complies with EMC Standards
  • 100% full load aging test
  • Power Input: AC90-264V
  • Operation temperature: -40℃ to 70℃
  • High efficiency, long lifespan, and high reliability
  • Provides protection against short circuit, overcurrent, and overvoltage

Applications

  • Factory automation
  • Industrial Control Systems
  • Electro-mechanical apparatus
  • Semiconductor fabrication equipment

Dimension

GWS-DP60-12 Industrial DIN Rail Power Supply dimensional drawing